EZLite HxS

The EZLite-HxS series gives spectral data within a +/- 60° viewing cone.
You get a full spectral map made in less than 3mn. With 15 bandpass filters regularly distributed in the middle range, the EZLite-HxS is your solution for an angular spectral analysis. 

 

Overview

The EZLite-HxS series gives spectral data within a +/- 60° viewing cone.
You get a full spectral map made in less than 3mn. With 15 bandpass filters regularly distributed in the middle range, the EZLite-HxS is your solution for an angular spectral analysis. 

FEATURES

  • Non-contact measurement
  • Fast spectral measurements
  • Radiance, luminance and colour data
  • High accuracy and reliability
  • Cooled CCD sensor

Specifications

Specifications EZLite-HxS
Viewing Angle Incident angle
Azimuth angle
±60°
0-360°
Measuring area Diameters 2mm, 1mm, 500μm, & 300μm
Density Set of neutral density
Polarization Optimal 3 polarizers: 0, 45 & 90°
and 2 wave-plates (*)
Optimum distance (To ensure the light is coming from the same spot at any angle) 4,5mm
Spectral specs Standard
Optional
Spectral data extraction
15 bandpass filters on the visible range 400-700nm
2 additional bandpass filters between700 and 900nm
Interpolation with steps between 1 and 5nm
Measurement time Radiance with full resolution
Radiance with half-resolution
Polarization with full resolution
<6mn (*2)
<3mn (*2)
<15mn (*2)
Accuracy Wavelength resolution (nm)
Wavelength accuracy (nm)
Stray light (%)
Angular resolution (deg)
Radiance (W/Str/m2/nm)
Chromaticity
Ellipticity & polarization direction
Polarization degree
20
1(*3)
<0.1(*4)
0.75
±5%
0.005 (for any stimulus)
±2° up to 60°
±2% up to 60°
Repeatability Radiance
Luminance
Chromaticity
±0.05% (*2)
±0.05% (*2)
0.001(*2)
Reflective options Only Diffused
Use conditions Temperature range
Humidity range
0 to 30°C
0-85% non condensing
Interface USB 2.0
Power AC adapter (100-240V 50/60Hz)
Current consumption 90W
Weight 10Kg
(*¹) Driven by software
(*²) Measuring times are highly dependent on the target and on the conditions. Given times are for a source with a radiance level higher than 10mW/Sr/m²/nm at all the wavelength and already determined exposition times for all the filters.
(*³) Bandpass filters with a FWHM of about 20nm: the reported accuracy is on the bandpass central wavelength position.
(*⁴) For one filter with regards to the maximum of radiance observed on all the other filters.
Specifications can be changed without notice

Applications

APPLICATIONS

  •  Physico-realistic simulation
  •  All kind of displays performances characterization in details
  •  Grey levels analysis

Resources

Accessories

Request Info/Demo