EZLite HxS
The EZLite-HxS series gives spectral data within a +/- 60° viewing cone.
You get a full spectral map made in less than 3mn. With 15 bandpass filters regularly distributed in the middle range, the EZLite-HxS is your solution for an angular spectral analysis.
Overview
The EZLite-HxS series gives spectral data within a +/- 60° viewing cone.
You get a full spectral map made in less than 3mn. With 15 bandpass filters regularly distributed in the middle range, the EZLite-HxS is your solution for an angular spectral analysis.
FEATURES
- Non-contact measurement
- Fast spectral measurements
- Radiance, luminance and colour data
- High accuracy and reliability
- Cooled CCD sensor
Specifications
Specifications |
|
EZLite-HxS |
Viewing Angle |
Incident angle
Azimuth angle |
±60°
0-360° |
Measuring area |
Diameters |
2mm, 1mm, 500μm, & 300μm |
Density |
|
Set of neutral density |
Polarization |
Optimal |
3 polarizers: 0, 45 & 90°
and 2 wave-plates (*) |
Optimum distance |
(To ensure the light is coming from the same spot at any angle) |
4,5mm |
Spectral specs |
Standard
Optional
Spectral data extraction |
15 bandpass filters on the visible range 400-700nm
2 additional bandpass filters between700 and 900nm
Interpolation with steps between 1 and 5nm |
Measurement time |
Radiance with full resolution
Radiance with half-resolution
Polarization with full resolution |
<6mn (*2)
<3mn (*2)
<15mn (*2) |
Accuracy |
Wavelength resolution (nm)
Wavelength accuracy (nm)
Stray light (%)
Angular resolution (deg)
Radiance (W/Str/m2/nm)
Chromaticity
Ellipticity & polarization direction
Polarization degree |
20
1(*3)
<0.1(*4)
0.75
±5%
0.005 (for any stimulus)
±2° up to 60°
±2% up to 60° |
Repeatability |
Radiance
Luminance
Chromaticity |
±0.05% (*2)
±0.05% (*2)
0.001(*2) |
Reflective options |
Only Diffused |
Use conditions |
Temperature range
Humidity range |
0 to 30°C
0-85% non condensing |
Interface |
USB 2.0 |
Power |
AC adapter (100-240V 50/60Hz) |
Current consumption |
90W |
Weight |
10Kg |
(*¹) Driven by software |
(*²) Measuring times are highly dependent on the target and on the conditions. Given times are for a source with a radiance level higher than 10mW/Sr/m²/nm at all the wavelength and already determined exposition times for all the filters. |
(*³) Bandpass filters with a FWHM of about 20nm: the reported accuracy is on the bandpass central wavelength position. |
(*⁴) For one filter with regards to the maximum of radiance observed on all the other filters. |
Specifications can be changed without notice |
Applications
APPLICATIONS
- Physico-realistic simulation
- All kind of displays performances characterization in details
- Grey levels analysis
Thank you for viewing our product catalogue. For more information or to request a product demo please call a Product Expert at 343.700.0688 Dismiss